Name:

SIL 3 Digital Output Driver, NE Loads Bus Powered

Type:

Digital Output

Show similar products
Supply:

24 Vdc nom (20 to 30 Vdc)

Field device:

Show similar products
Channels:

1

Description:

The single channel Bus Powered Digital Output Isolator, D5049S, is suitable for driving solenoid valves, visual or audible alarms to alert a plant operator, or other process control devices in Hazardous Area from a driving signal in Safe Area. It can also be used as a controllable supply to power measuring or process control equipment.
Its use is allowed in applications requiring up to SIL 3 level (according to IEC 61508) in safety related systems for high risk industries.
The Safety PLC or DCS driving signal controls the field device through the D5049S, which provides isolation and is capable of monitoring the conditions of the line.
Short and open circuit diagnostic monitoring, dip-switch selectable, operates irrespective of the channel condition and provides LED indication and NC transistor output signaling.
When fault is detected output is de-energized until normal condition is restored.
An override input, dip-switch selectable, is provided to permit a safety system to override the control signal. When enabled, a low input voltage always de-energizes the field device regardless of the input signal.
Three basic output circuits are selectable, with different safety parameters, to interface the majority of devices on the market. The selection among the three output characteristics is obtained by connecting the field device to a different terminal block.

Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area / Non Hazardous Location or in Zone 2 / Class I,Division 2 or Class I, Zone 2.

Features:

• Output to Zone 0 (Zone 20) / Division 1,installation in Zone 2 / Division 2.
• Bus powered for NE loads.
• Short and open circuit line diagnostic monitoring with LED, transistor output.
• Output short circuit proof and current limited.
• Three port isolation, Input/Output/Supply.
• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system.
• In-field programmability by DIP Switch.
• Simplified installation using standard DIN-Railand plug-in terminal blocks, with or without Power Bus, or customized Termination Boards.
• 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.

SIL level:

SIL 3

Data sheet:
DTS0287 D5049S data sheet (English) (PDF 358 KB)
Instruction manual:
ISM0120D5049S instruction manual (PDF 689 KB)
ISM0121D5000-D5200 Series General Instruction Manual (PDF 3.27 MB)
ISM0163FM Control Drawing for D5048S, D5049S (PDF 149 KB)
ISM0156D5000 Series Safety Instruction Manual (PDF 5.24 MB)
ISM0279UL Control Drawing for D5048S, D5049S (PDF 96 KB)
Certifications:
CRT005UL & C-UL barriers listing [link E222308] (PDF 227 KB)
CRT058ATEX certificate n. BVS 10 ATEX E 113 X (PDF 4.61 MB)
CRT062IECEx CoC for D5000 Series [link IECEx BVS 10.0072X] (PDF 8.31 MB)
CRT084Metrological Certificate for D5000 Series (Russia) (PDF 2.13 MB)
CRT110FM 3046304 (USA) & FM-C 3046304C (Canada) for D5000 Series (PDF 314 KB)
CRT126DNV Maritime Type Approval Certificate (D5000 Series) (PDF 1.68 MB)
CRT127INMETRO Certificate DNV 13.0109 X (PDF 619 KB)
CRT128TÜV SIL Certificate Summary (PDF 1.97 MB)
CRT130TÜV SIL Functional Safety Certificate (PDF 65 KB)
CRT136TRCU Certificate for D5000 Series (PDF 1.35 MB)
CRT153Korean Register Type Approval Certificate (PDF 1.22 MB)
CRT169NEPSI cert. no. GYJ14.1406X (PDF 6.93 MB)
CRT187TIIS Certificate for D5048, D5049 (PDF 3.87 MB)
CRT218Ukraine certificate for D5000 series (PDF 2.80 MB)
Accessories:
JDFT04912mm DIN Rail Connector
MCHP196Power Bus Terminal Block Cover and Fix
MOR017Plug-in Terminal Block male, Horizontal Output, for Bus Power
MOR022Plug-in Terminal Block female, Horizontal Output, for Bus Power
Various:
2D drawing of D5000 Series in DWG format (DWG 54 KB)
3D drawing of D5000 Series in DWG format (DWG 2.26 MB)
3D drawing of D5000 Series in STEP format (STEP 5.92 MB)
Conformal Coating Declaration (PDF 135 KB)
D5000 Dimensional Drawing (PDF 217 KB)
EU Declaration of Conformity DTS0369 (PDF 235 KB)
IECEx Declaration of Conformity DTS0372 (PDF 135 KB)
REACh, RoHS Declaration of Conformity (PDF 150 KB)

D5049S - SIL 3 Digital Output Driver, NE Loads, Loop Powered

Click to enlarge
Are you interested in this product? Request a quotation, search for an expert in your area or contact us.


Home | Products | Download | Contacts | Site map
Products:
©

G.M. International srl

Via G. Mameli, 53-55
I-20852 Villasanta (MB)
ITALY
Tel: +39 039 2325038
Fax: +39 039 2325107

P. IVA / C.F. : 02312650969
REA: MI1418125
Cap. Soc.: 93600 €