We are using cookies to give you the best experience on our site. Cookies are files stored in your browser and are used by most websites to personalise your navigation. By clicking the Accept button or continuing to browse, you agree with our use of cookies. Click here for more information.
GM International
Log in or Sign up |          


Products:
 

D5072S

Code:

D5072S

Products comparison or request a quotation
Name:

SIL 2 Temperature Signal Converter, Multifunction

Type:

Temperature Input

Show similar products
Supply:

24 Vdc nom (20 to 30 Vdc)

Field device:

Show similar products
Channels:

1 (2 channels: D5072D)

Description:

The single channel Temperature Signal Converter, D5072S, accepts a low level dc signal from millivolt, thermocouple or 2-3-4 wire resistance/RTD or transmitting potentiometer sensor, located in Hazardous Area, and converts, with isolation, the signal to drive a Safe Area load, suitable for applications requiring SIL 2 level (according to IEC 61511) in safety related systems for high risk industries. Output signal can be direct or reverse. Modbus RTU RS-485 output is available on Bus connector.
Cold junction compensation can be programmed as:
- Automatic: provided by an internal temperature sensor;
- Fixed: to a user-customizable temperature value;
Output function can be configured as: Adder, subtractor, low/high selector.
Modules are provided with alarm function, which is available via photoMOS output, Termination Board and Power Bus.

Mounting on standard DIN-Rail, with or without Power Bus, or on customized Termination Boards, in Safe Area / Non Hazardous Location or in Zone 2 / Class I, Division 2 or Class I, Zone 2.

Hazardous area:

millivolt or thermocouple type A1, A2, A3, B, E, J, K, L, LR, N, R, S, T, U, or 2-3-4 wire RTD Pt50, Pt100, Pt200, Pt300, Pt400, Pt500, Pt1000 to IEC, Pt100 to ANSI (0.3916), Ni100, Ni120 to DIN43760, Pt46, Pt50, Pt100, Pt200, Pt300, Pt400, Pt500, Cu50, Cu53, Cu100 to GOST6651 (russian standard) and Cu9.035 (or Cu10), or 3 wire transmitting potentiometer (100 Ω to 10 kΩ). 4-wire RTD input only on D5072S. Possibility of configuring user customized sensor (TC or RTD). Choice between °C/°F.

Safe area:

Fully customizable 0/4 to 20 mA, Sink or Source.

Features:

• Input from Zone 0 (Zone 20) / Division 1, installation in Zone 2 / Division 2.
• mV, thermocouple, 2 or 3 or 4 wire resistance/RTD or transmitting potentiometer Input Signal.
• 2-wire RTD line resistance compensation.
• Internal Reference Junction Compensation automatic or fixed (programmable value).
• Fastest integration time: 50 ms
• Fully customizable Output range from 0 to 24 mA
• Output Signal linear or reverse (typical 0/4-20 mA).
• Modbus RTU RS-485 Output.
• Independent multiple Fault detection.
• Programmable alarm available on photoMOS output or Termination Board connector.
• High Accuracy, μP controlled A/D converter.
• Three port isolation, Input/Output/Supply.
• EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1, EN61326-3-1 for safety system.
• Fully programmable operating parameters.
• High Density, two channels per unit.
• Simplified installation using standard DIN-Rail and plug-in terminal blocks, with or without Power Bus, or customized Termination Boards.
• 250 Vrms (Um) max. voltage allowed to the instruments associated with the barrier.
• Data logging and monitoring via software.

SIL level:

SIL 2

Data sheet:
DTS0288 D5072S data sheet (English) (PDF 676 KB)
Instruction manual:
ISM0154SWC5090 Instruction Manual (PDF 5.57 MB)
ISM0157D5072S instruction manual (PDF 1.32 MB)
ISM0121D5000-D5200 Series General Instruction Manual (PDF 3.27 MB)
ISM0166FM Control Drawing for D5072S, D5072D (PDF 144 KB)
ISM0156D5000 Series Safety Instruction Manual (PDF 5.24 MB)
Certifications:
CRT087ATEX certificate n. BVS 12 ATEX E 053 X (PDF 4.13 MB)
CRT090IECEx CoC for D5072S/D, D5072S-087, D5273S [link IECEx BVS 12.0050X] (PDF 1.72 MB)
CRT110FM 3046304 (USA) & FM-C 3046304C (Canada) for D5000 Series (PDF 314 KB)
CRT112Metrological Certificate for D5072, D5273 (Russia) (PDF 480 KB)
CRT123INMETRO Certificate DNV 13.0110 X (PDF 449 KB)
CRT126DNV Maritime Type Approval Certificate (D5000 Series) (PDF 1.68 MB)
CRT142TÜV SIL Certificate Summary (PDF 919 KB)
CRT153Korean Register Type Approval Certificate (PDF 1.22 MB)
CRT169NEPSI cert. no. GYJ14.1406X (PDF 6.93 MB)
CRT218Ukraine certificate for D5000 series (PDF 2.80 MB)
CRT230TRCU Certificate for D5072, D5273, D5036, D5037 Series (PDF 1.39 MB)
CRT253Metrological Certificate for D5000/D6000 Series (Belarus) (PDF 1.80 MB)
Software:
SWC5090D5000/D6000 Software Configurator for Windows
Accessories:
JDFT04912mm DIN Rail Connector
MCHP196Power Bus Terminal Block Cover and Fix
MOR017Plug-in Terminal Block male, Horizontal Output, for Bus Power
MOR022Plug-in Terminal Block female, Horizontal Output, for Bus Power
PPC5092D5000 Series Adapter for Configuration
Various:
2D drawing of D5000 Series in DWG format (DWG 54 KB)
3D drawing of D5000 Series in DWG format (DWG 2.26 MB)
3D drawing of D5000 Series in STEP format (STEP 5.92 MB)
Conformal Coating Declaration (PDF 135 KB)
D5000 Dimensional Drawing (PDF 217 KB)
EU Declaration of conformity DTS0471 (PDF 240 KB)
IECEx Declaration of conformity DTS0472 (PDF 133 KB)
REACh, RoHS Declaration of Conformity (PDF 150 KB)

D5072S - SIL 2 Temperature Signal Converter

Click to enlarge
Are you interested in this product? Request a quotation, search for an expert in your area or contact us.


Home | Products | Download | Contacts | Site map
Products:
©

G.M. International srl

Via G. Mameli, 53-55
I-20852 Villasanta (MB)
ITALY
Tel: +39 039 2325038
Fax: +39 039 2325107

P. IVA / C.F. : 02312650969
REA: MI1418125